Door and fire

Fire-Rated Doors for Victoria and Vancouver Island

Annual Inspections

LocksRus is your trusted source and mobile service for all fire-rated doors from Victoria to Bella Bella. We are currently offering annual inspections per National Fire Protection Association (NFPA) standards. All of our inspections are performed as per NFPA 80 guidelines.


Our services include:

  • Inspecting each fire-rated door to NFPA 80 requirements
  • Provide a report for each door, listing deficiencies and necessary repairs
  • Accurate fire rated door inventory using either your existing numbering system or creating a system for you
  • Maintenance options and agreements are available


Contact us today to get pricing information. You will be glad you did!


NFPA Inspection Guidelines

NFPA 80 sets the standard for annual fire door inspections. At a minimum, your fire doors must be inspected no less than annually and a signed copy of the inspection report must be on field for the AHJ to review. (Source NFPA 80, 5.2.1-5.2.4.2, 2007 edition)


Standards for Fire Doors and Other Opening Protectives (2010 Edition)

4.9 – Testing

4.9.1 – Upon completion of installation, all fire door and fire window assemblies shall be tested to confirm operation of the automatic closing device and full closure.

4.9.2 – Resetting of the automatic closing device shall be in accordance with the manufacturer’s written instructions.

4.9.3 – A written record shall be maintained and be made available to the AHJ.

5.1.1.2 – The requirements of this chapter shall apply to new and existing installations.

5.1.4 – Replacement. Where it is necessary to replace fire doors, shutters, windows or their frames, glazing materials, hardware and closing mechanisms, replacements shall meet the requirements for fire protection and shall be installed as required by this standard for new installations.


Fire Door Assembly Inspection FAQ

The 2007 edition of NFPA 80 – Standard for Fire Doors and Other Opening Protectives (section 5.2 Inspections) requires all fire doors to be inspected not less than annually. As states, municipalities and building / life-safety codes adopt or reference this edition of the standard; this requirement becomes effective and enforceable.


Q: Who is responsible to make sure the inspections are performed?

It is the responsibility of building owners and property managers to initiate the inspections and produce written records of the inspections for the code official to review.


Q: What are the record-keeping requirements?

NFPA 80 does not detail the requirements for record-keeping except that the documentation must be signed, but code officials may have their own requirements.


Q: What will be checked during the inspection process?

  • No open holes or breaks in the surface of the door or frame; no missing or broken parts
  • Glazing, vision light frames, and glazing beads intact and securely fastened
  • Door, frame, hinges, hardware, and thresholds secured, aligned, in working order and without damage
  • Proper clearance between door and frame, between meeting stiles of pairs, and at bottom of door
  • Self-closing devices and coordinators (where applicable) operational
  • Latching hardware operates and secures door in closed position
  • Auxiliary items that would interfere with operation are not installed
  • No field modifications have been performed that void the label; labels are present and visible
  • Gasketing and edge seals are present and in good condition


Q: If deficiencies are found, when must they be repaired?

Repairs shall be made and defects that could interfere with operation shall be corrected, without delay. (5.1.5.1)


Find Doors that are Safe for Your Business

Open the door to safety with LocksRus. We are a full service wood door supplier and have a full line of fire-rated products listed with Intertek Testing Services, making our products an ideal choice for all types of commercial or semi-residential construction. LocksRus offers a variety of door cores for your specific temperature rise, R-value and security requirements.


Enhance Your Safety with Our Hollow Metal Doors

Ask about our full selection of hollow metal products that are manufactured using satin coat steel. Our metal doors are manufactured from 20-gauge steel to 12-gauge steel and can be provided with lock seam of fully welded construction.


We are pleased to offer:

  • Acoustic wooden doors
  • Fire-rated wooden doors
  • Wood doors in metal door frames
  • Pre-hung wooden doors and frames
  • Hollow metal doors and frames

LocksRus has a full range of knockdown frame parts available in the following steel thickness:

  • 20-gauge
  • 18-gauge
  • 16-gauge
  • 14-gauge

Welded frames, side lights and borrowed lights are available in the following steel thickness:

  • 16-gauge
  • 14-gauge
  • 12-gauge
Get fire protection today Get answers

Call for Mobile Services

Give us a call at your convenience and we can arrange a time so we can present our products and services to you and your colleagues.

Mobile services from Victoria to 

Bella Bella


Address

6965 Highland Drive

Port Hardy, BC, V0N 2P0


Phone

Telephone 250‑949‑0308


Email

info@locksrus.ca
quote@locksrus.ca

robert@locksrus.ca

Copyright LocksRus Solutions Inc. 2017 - Legal
Created by

Legal notice